Tabular foundation models are not a shortcut to calibrated clinical risk prediction: a pre-registered simulation against the true risk

Evaluates calibration of tabular foundation models versus logistic regression in simulated and clinical risk prediction.

Abstract

Tabular foundation models are pretrained networks that predict risk from a table without fitting a model. Whether their risks are correct (calibrated) has been judged on real data, where true risk is unknown. In a pre-registered simulation with known true risks, we compared TabPFN-3.5, TabICLv2 and Mitra-v2 with Firth logistic regression with intercept correction (FLIC) in 58 scenarios and 1,000 random designs, then on four clinical data sets. Foundation models were not a shortcut to calibration. Their calibration slope matched FLIC’s within the pre-registered margin in 36 or 37 of 48 core scenarios and was better only at n = 200 with a 3% event rate. Even 3,000 patients were often not enough: with FLIC, TabPFN-3.5 or Mitra-v2, 63%-83% of samples gave risks close to the truth in average, intercept and slope at event rates of 10% and 30%, and 35%-50% at 3%. TabICLv2 did worse (8%-39% and 1%-3%). Across the random designs, foundation models had a lower true calibration error than FLIC beyond the margin in 25%-38% and a higher one in none, though small losses were predicted at n = 3000. On real data, no model resisted a change in event rate between populations; recalibration on 500 local patients largely repaired it.